ISSUE Date Customer Machine, Model, Serial No. Problem Progress Executor Status Priority

Dual Lane SMema has malfunction. [Delta 2]

May 12, 2026 Delta AXI,TR7600 SIII, T2002770416-002

The machine sent out PCB wrong lane (Dual Lane SMema).

During follow-up troubleshooting guideline from RD team.

June open MEDIUM

Dual Lane SMema has malfunction. [Delta 2]

May 19, 2026 Delta AXI,TR7600 SIII, T2002770416-002

The machine sent out PCB wrong lane (Dual Lane SMema).

- During follow-up troubleshooting guideline from RD team.

- Plan to re-check wiring SMema again on 21'May'2026.

June on going MEDIUM

Dual Lane SMema has malfunction. [Delta 2]

May 26, 2026 Delta AXI,TR7600 SIII, T2002770416-002

The machine sent out PCB wrong lane (Dual Lane SMema).

1.After check signal and wiring on 21'May'2026.found signal logic of previously machine(PASS=Open/FAIL=Short) which not matching with our AXI (PASS=Short/FAIL=Open)

2.Summary result to RD and continue follow-up.

June on going MEDIUM

Dual Lane SMema has malfunction. [Delta 2]

June 5, 2026 Delta AXI,TR7600 SIII, T2002770416-002

The machine sent out PCB wrong lane (Dual Lane SMema).

1.RD request the PLC file.
--> Waiting PLC file from customer.

2.Continue followup with RD.

June on going MEDIUM

Dual Lane SMema has malfunction. [Delta 2]

June 10, 2026 Delta AXI,TR7600 SIII, T2002770416-002

The machine sent out PCB wrong lane (Dual Lane SMema).

1.RD request the PLC file. --> Already send to RD.

2.Require test upload & test PLC at line As11
--> Plan to test on 11-12 Jun 2026

June on going MEDIUM

Dual Lane SMema has malfunction. [Delta 2]

June 15, 2026 Delta AXI,TR7600 SIII, T2002770416-002

The machine sent out PCB wrong lane (Dual Lane SMema).

Require test upload & test PLC at line AS11
--> Plan to test on 17,18 Jun 2026 (wait confirm with customer)

June on going MEDIUM

Dual Lane SMema has malfunction. [Delta 2]

June 25, 2026 Delta AXI,TR7600 SIII, T2002770416-002

The machine sent out PCB wrong lane (Dual Lane SMema).

Require test upload & test PLC at line AS10 (VPLC 2.16)
--> Test result still found same issue

Next : Continue followup with RD

June on going MEDIUM