ISSUE Date Customer Machine, Model, Serial No. Problem Progress Executor Status Priority

Main software malfunction when using multiple block scan

June 5, 2026 Benchmark AXI,TR7600 SIII, T2003030699-002

Main SW status stuck in step "Block scan" (Motion stopped) and Main PC restart automatically.

1.Send all log and RCP to RD --> Done (7/Jun/26)

2.RD require to testing with ver 3.6.92.2 (CAD Mode)
-->Waitng (8/Jun/26)

Ton open MEDIUM

Main software malfunction when using multiple block scan

June 10, 2026 Benchmark AXI,TR7600 SIII, T2003030699-002

Main SW status stuck in step "Block scan" (Motion stopped) and Main PC restart automatically.

1.Send all log and RCP to RD --> Done (7/Jun/26)

2.RD require to testing with ver 3.6.92.2 (CAD Mode)
-->Test done , Found same issue both inspection mode.

3.Install Hwinfo for tracking CPU temp. & Continue followup with RD

Ton on going MEDIUM

Main software malfunction when using multiple block scan

June 15, 2026 Benchmark AXI,TR7600 SIII, T2003030699-002

Main SW status stuck in step "Block scan" (Motion stopped) and Main PC restart automatically.

1.Install Hwinfo for tracking CPU temp. & Continue followup with RD --> Monitoring

Ton on going MEDIUM

Main software malfunction when using multiple block scan

June 25, 2026 Benchmark AXI,TR7600 SIII, T2003030699-002

Main SW status stuck in step "Block scan" (Motion stopped) and Main PC restart automatically.

1.Install Hwinfo for tracking CPU temp. & Continue followup with RD --> Monitoring

Ton on going MEDIUM

Main software malfunction when using multiple block scan

July 3, 2026 Benchmark AXI,TR7600 SIII, T2003030699-002

Main SW status stuck in step "Block scan" (Motion stopped) and Main PC restart automatically.

Waiting for the error again, then send log to HQ.

Ton on going MEDIUM

Main software malfunction when using multiple block scan

July 10, 2026 Benchmark AXI,TR7600 SIII, T2003030699-002

Main SW status stuck in step "Block scan" (Motion stopped) and Main PC restart automatically.

Waiting RD Check log. Already sent the log to HQ.

Ton on going MEDIUM

Main software malfunction when using multiple block scan

July 17, 2026 Benchmark AXI,TR7600 SIII, T2003030699-002

Main SW status stuck in step "Block scan" (Motion stopped) and Main PC restart automatically.

send beta vertion to customer to test TR7600Ver3_6_92_6_Official_20260717

Ton on going MEDIUM

Main software malfunction when using multiple block scan

July 24, 2026 Benchmark AXI,TR7600 SIII, T2003030699-002

Main SW status stuck in step "Block scan" (Motion stopped) and Main PC restart automatically.

Beta version can't send image out to RS, waiting new version update.

Ton on going MEDIUM

Main software malfunction when using multiple block scan

July 31, 2026 Benchmark AXI,TR7600 SIII, T2003030699-002

Main SW status stuck in step "Block scan" (Motion stopped) and Main PC restart automatically.

Waiting for new SW around 2 weeks.

Ton on going MEDIUM

Main software malfunction when using multiple block scan

Aug. 7, 2026 Benchmark AXI,TR7600 SIII, T2003030699-002

Main SW status stuck in step "Block scan" (Motion stopped) and Main PC restart automatically.

Waiting for new SW around 2 weeks.

Ton on going MEDIUM

Main software malfunction when using multiple block scan

Aug. 14, 2026 Benchmark AXI,TR7600 SIII, T2003030699-002

Main SW status stuck in step "Block scan" (Motion stopped) and Main PC restart automatically.

Send SW the new version to Nichtech

Ton on going MEDIUM