Issues for AXI (WW12/2026)

Machine Issue Customer Progress Executor Status
AXI 2D camera has purple color when decode barcode Delta - On April this machine will has yearly maintenance. I will do 2D camera again khaw on going
AXI Out of Focus (OOF) for server board QMB - Fine-tune model A5G-MB at p27 line can reduce false calls and keep monitoring this issue. - K17 A7S_PB model and N27 A5G-YB this week no plan to produce khaw on going
AXI Defect Escape (DIMM) QMB -After import AI model found the AI still escape DIMM connector defect some pin - Collect the images that AI escapes and sent to RD to retrain new AI model khaw on going
AXI Breaker trip when test ups TR7600 SIII (Benchmark) Benchmark HQ will send part out 27 Mar ton on going
AXI X-Ray image quality going blur after change the 2D fixture Hanwha - Did redo the software limit position follow your SOP, after setting completed the X-ray image quality is still blurred, it is not as sharp as before. khaw open