Machine Issue Customer Progress Executor Status
AXI 2D camera has purple color when decode barcode Delta - On April this machine will has yearly maintenance. I will do 2D camera again khaw on going
AXI Defect Escape (DIMM) QMB -After import AI model found the AI still escape DIMM connector defect some pin - Collect the images that AI escapes and sent to RD to retrain new AI model khaw on going
AXI Out of Focus (OOF) for server board QMB - Fine-tune K17 A7S_PB model, N27 A5G-YB model, and A5G-MB at p27 line can reduce false calls and keep monitoring this issue. khaw on going
AXI RS AI Verify Host NA - keep monitoring about AI escape pin defect or not - Found AI escape pin at line Q27 collect images and send back to RD khaw on going
AXI X-Ray image quality going blur after change the 2D fixture Hanwha - Did redo the software limit position follow your SOP, after setting completed the X-ray image quality is still blurred, it is not as sharp as before. - Request the calibration jig from HQ. In process waiting calibration from HQ khaw on going