| AXI |
2D camera has purple color when decode barcode |
Delta |
- On April this machine will has yearly maintenance. I will do 2D camera again |
khaw |
on going |
| AXI |
API Delta Develop auto assign function for multi models in one panel |
Delta |
Yuchia suggested
add a SNQuery ON/OFF button in the SFC setting.
0.please change SFCSystem.exe to latest one in the attached file.
if you only needs RouteCheck and no need SN Query.
please
1. turn ON Upload API CheckBarcode in the MES81 setting
2. turn OFF SNQuery in the SFC setting
- Waiting customer test this function |
khaw |
on going |
| AXI |
Defect Escape (DIMM) |
QMB |
- Keep monitor the false call and pin escape |
khaw |
on going |
| AXI |
Out of Focus (OOF) for server board |
QMB |
- Fine-tune K17 A7S_PB model, N27 A5G-YB model, and A5G-MB at p27 line can reduce false calls and keep monitoring this issue. |
khaw |
on going |
| AXI |
X-Ray image quality going blur after change the 2D fixture |
Hanwha |
- Did redo the software limit position follow your SOP, after setting completed the X-ray image quality is still blurred, it is not as sharp as before.
- Request the calibration jig from HQ. In process waiting calibration from HQ |
khaw |
on going |
| AXI |
Shield Can Defect |
Hanwha |
- HQ suggest try to use the PF Height algorithm to check the Shield Can defect.
- Will try to test this algorithm, if work properly or not |
khaw |
on going |
| AXI |
RS AI Verify Host |
NA |
that Bill has connected RS AI. The 4 lines are P27, Q27, U17 and U27 lines. These four lines can show the AI results judgment.
Remark: at RS AI Host, Bill disables RS centralized Backup. So we can’t check AI judgment result and can’t generate AI report at RS AI Host. If we want to generate AI report need to do at RS station each production line. |
khaw |
on going |
| AXI |
Breaker trip when test ups TR7600 SIII (Benchmark) |
Benchmark |
After changing the machine can run normally. |
ton |
closed |
| AXI |
API Delta Develop auto assign function for multi models in one panel |
Delta |
Yuchia suggested
add a SNQuery ON/OFF button in the SFC setting.
0.please change SFCSystem.exe to latest one in the attached file.
if you only needs RouteCheck and no need SN Query.
please
1. turn ON Upload API CheckBarcode in the MES81 setting
2. turn OFF SNQuery in the SFC setting |
khaw |
open |
| AXI |
Shield Can Defect |
Hanwha |
- HQ suggest try to use the PF Height algorithm to check the Shield Can defect. |
khaw |
open |