| AXI |
2D camera has purple color when decode barcode |
Delta |
- On April this machine will has yearly maintenance. I will do 2D camera again |
khaw |
on going |
| AXI |
API Delta Develop auto assign function for multi models in one panel |
Delta |
- Waiting customer test the new function |
khaw |
on going |
| AXI |
Defect Escape (DIMM) |
QMB |
- Keep monitor the false call and pin escape |
khaw |
on going |
| AXI |
Out of Focus (OOF) for server board |
QMB |
- keep monitoring this issue. |
khaw |
on going |
| AXI |
RS AI Verify Host |
NA |
- Update RS AI Host to new version and update RS software to V4.0.0.9_20260506 version at Q27 line |
khaw |
on going |
| AXI |
Shield Can Defect |
Hanwha |
- R&D tried to use the Solder JointHeight CT algorithm. This algorithm is the most similar to the concept as request from Mr.Choi (Mr. Choi’s concept as an image below), which can measure the height of the BGA Solder Joint height, but it isn’t suitable for this defect. So, we can’t meet the target of Mr. Choi’s concept.
- RD tried to use two algorithms, “Solder Area” and “Open Sharpness”, were applied for component inspection. While all defects can be successfully detected, the false alarm rate remains relatively high. |
khaw |
on going |
| AXI |
X-Ray image quality going blur after change the 2D fixture |
Hanwha |
- Did redo the software limit position follow your SOP, after setting completed the X-ray image quality is still blurred, it is not as sharp as before.
- Request the calibration jig from HQ. In process waiting calibration from HQ
- HQ confrim will ship the Jig on 22 May |
khaw |