Issues for AXI (WW20/2026)

Machine Issue Customer Progress Executor Status
AXI 2D camera has purple color when decode barcode Delta - Waiting this machine to have yearly maintenance. I will do 2D camera again khaw on going
AXI API Delta Develop auto assign function for multi models in one panel Delta - Waiting customer test the new function khaw on going
AXI Defect Escape (DIMM) QMB - Keep monitor the false call and pin escape khaw on going
AXI Out of Focus (OOF) for server board QMB - keep monitoring this issue. khaw on going
AXI RS AI Verify Host NA - Update RS AI Host to new version and update RS software to V4.0.0.9_20260506 version at Q27 and P27 lines khaw on going
AXI Shield Can Defect Hanwha - RD tried to use two algorithms, “Solder Area” and “Open Sharpness”, were applied for component inspection. While all defects can be successfully detected, the false alarm rate remains relatively high. - Will find the free time to fine-tune for reduce false call khaw on going
AXI X-Ray image quality going blur after change the 2D fixture Hanwha - Did redo the software limit position follow your SOP, after setting completed the X-ray image quality is still blurred, it is not as sharp as before. - Request the calibration jig from HQ. In process waiting calibration from HQ - HQ confrim will ship the Jig on 22 May -RD Henry and PM Richard checked the issue with us together, but the root cause has not been identified yet. RD Henry will assist us with further analysis next Monday khaw on going
AXI Dual Lane SMema has malfunction. [Delta 2] Delta During follow-up troubleshooting guideline from RD team. june open
AXI Software License for mango server [Benchmark AY] Benchmark During followup with RD team. june open
AXI X-ray power ON lamp broken Benchmark - Wait P/N for new part from Taiwan. june open