Issues for AXI (WW21/2026)

Machine Issue Customer Progress Executor Status
AXI 2D camera has purple color when decode barcode Delta - Waiting this machine to have yearly maintenance. I will do 2D camera again khaw on going
AXI API Delta Develop auto assign function for multi models in one panel Delta - Waiting customer test the new function khaw on going
AXI Defect Escape (DIMM) QMB - Keep monitor the false call and pin escape khaw on going
AXI Out of Focus (OOF) for server board QMB - keep monitoring this issue. khaw on going
AXI RS AI Verify Host NA - Update RS AI Host to new version and update RS software to V4.0.0.9_20260506 version at Q27 and P27 lines khaw on going
AXI Shield Can Defect Hanwha - RD tried to use two algorithms, “Solder Area” and “Open Sharpness”, were applied for component inspection. While all defects can be successfully detected, the false alarm rate remains relatively high. - Will find the free time to fine-tune for reduce false call khaw on going
AXI X-Ray image quality going blur after change the 2D fixture Hanwha -RD Henry and PM Richard checked the issue with us together, but the root cause has not been identified yet. RD Henry will assist us with further analysis next time - This week customer postponed the plan due to has end customer visit the site khaw on going
AXI Dual Lane SMema has malfunction. [Delta 2] Delta - During follow-up troubleshooting guideline from RD team. - Plan to re-check wiring SMema again on 21'May'2026. june on going
AXI Software License for mango server [Benchmark AY] Benchmark 1.The Policy of TRI can't provide software license. 2.The customer has change new concept of server storage (MES report only) --> Customer request expand to all machine on 20'May'26 june on going