| AXI |
2D camera has purple color when decode barcode |
Delta |
- Waiting this machine to have yearly maintenance. I will do 2D camera again |
khaw |
on going |
| AXI |
API Delta Develop auto assign function for multi models in one panel |
Delta |
- Waiting customer test the new function |
khaw |
on going |
| AXI |
Auto calibration can't complete |
Calcomp |
- RD remote to check and redo Auto calibration again.
- RD said, the value of the Tube's z-axis movement is incorrect.
- Scott will help contact production line guys to check this issue
29/5
- After Scott confirmation with RD, the issue may be related to abnormal motion movement. We would like to ask you to use the motion controller to perform a movement test during next onsite visit.
Please verify whether the stage can reach the specified position correctly.
For example, input a movement distance of 10000 and check whether the stage actually moves 1 cm. |
khaw |
on going |
| AXI |
Defect Escape (DIMM) |
QMB |
- The 2 new AI models “MLMode_20260319l and MetelDimm_20260310_open_MLModel”. Bill was disabled last week due to it has a lot of false calls and back to used AI model name “QuantaDimm202504xx”.
- We need to retrain the AI model for both Type 1 and Type 2. Next time, please collect the Good Pins, Fail Pins, and missed-detection Pins for both Type 1 and Type 2, and the FAE team will perform the AI model training. |
khaw |
on going |
| AXI |
Out of Focus (OOF) for server board |
QMB |
- keep monitoring this issue.
- Teach Thai engineer how to set the warp with function Laser properties(laser offset, laser SR) and link only |
khaw |
on going |
| AXI |
RS AI Verify Host |
NA |
- Update RS AI Host to new version and update RS software to V4.0.0.9_20260506 version at Q27 and P27 lines
- Bill feedback about the location score of AI judgment, currently the score is shown behind the AI judgment detail. He wants us to change the location score of the AI judgment to show at the front of the AI judgment detail. For example (score)AIOK_AI judgement detail
- Bill said we still need to improve the AI coverage |
khaw |
on going |
| AXI |
Shield Can Defect |
Hanwha |
- RD tried to use two algorithms, “Solder Area” and “Open Sharpness”, were applied for component inspection. While all defects can be successfully detected, the false alarm rate remains relatively high.
- Will find the free time to fine-tune for reduce false call
- Currently, not yet continue fine-tine due to the x-ray will became blurry, sholud be solve the x-ray was blurry first |
khaw |
on going |
| AXI |
X-Ray image quality going blur after change the 2D fixture |
Hanwha |
29 May
- Did Auto Calibration. waiting for the result after the calibration complete |
khaw |
on going |
| AXI |
Dual Lane SMema has malfunction. [Delta 2] |
Delta |
1.After check signal and wiring on 21'May'2026.found signal logic of previously machine(PASS=Open/FAIL=Short) which not matching with our AXI (PASS=Short/FAIL=Open)
2.Summary result to RD and continue follow-up. |
june |
on going |
| AXI |
Software License for mango server [Benchmark AY] |
Benchmark |
1.The Policy of TRI can't provide software license. --> Done.
2.The customer has change new concept of server storage (MES report only) --> Expand to all machine with MES42 by temporary (Completed date : 21'May'2026) |
june |
on going |