Issues for AXI (WW24/2026)

Machine Issue Customer Progress Executor Status
AXI 2D camera has purple color when decode barcode Delta - Waiting this machine to have yearly maintenance. I will do calibrate 2D camera again khaw on going
AXI API Delta Develop auto assign function for multi models in one panel Delta - Waiting customer test the new function khaw on going
AXI Auto calibration can't complete Calcomp - 4/6 Asked the customer to check the motion movement of tube x-ray and camera, customer checked the motion movement of tube x-ray completed, the XYZ axis is move correctly. Customer will be looking free time to check the XYZ axis of camera - It is stilling customer to check motion movement khaw on going
AXI Defect Escape (DIMM) QMB - We need to retrain the AI model for both Type 1 and Type 2. Next time, please collect the Good Pins, Fail Pins, and missed-detection Pins for both Type 1 and Type 2, and the FAE team will perform the AI model training. khaw on going
AXI Out of Focus (OOF) for server board QMB - keep monitoring this issue and monitor false call at RS staion khaw on going
AXI RS AI Verify Host NA - Scott sent the new RS version to Bill, the location score of AI judgment is met Bill's require - Bill said we still need to improve the AI coverage - waiting customer send the RSAI images to retraining AI khaw on going
AXI Shield Can Defect Hanwha - RD tried to use two algorithms, “Solder Area” and “Open Sharpness”, were applied for component inspection. While all defects can be successfully detected, the false alarm rate remains relatively high. - Will find the free time to fine-tune for reduce false call - Currently, not yet continue fine-tine due to the x-ray will became blurry, sholud be solve the x-ray was blurry first khaw on going
AXI X-Ray image quality going blur after change the 2D fixture Hanwha - Maxym suggest to redo calibration by use official version khaw on going
AXI Dual Lane SMema has malfunction. [Delta 2] Delta 1.RD request the PLC file. --> Already send to RD. 2.Require test upload & test PLC at line As11 --> Plan to test on 11-12 Jun 2026 june on going
AXI Main software malfunction when using multiple block scan Benchmark 1.Send all log and RCP to RD --> Done (7/Jun/26) 2.RD require to testing with ver 3.6.92.2 (CAD Mode) -->Test done , Found same issue both inspection mode. 3.Install Hwinfo for tracking CPU temp. & Continue followup with RD june on going
AXI X-ray power ON lamp broken Benchmark -Wait warranty claim part from Taiwan. june on going