| AXI |
2D camera has purple color when decode barcode |
Delta |
- Waiting this machine to have yearly maintenance. I will do calibrate 2D camera again |
khaw |
on going |
| AXI |
API Delta Develop auto assign function for multi models in one panel |
Delta |
- Waiting customer test the new function |
khaw |
on going |
| AXI |
Auto calibration can't complete |
Calcomp |
- 4/6 Asked the customer to check the motion movement of tube x-ray and camera, customer checked the motion movement of tube x-ray completed, the XYZ axis is move correctly. Customer will be looking free time to check the XYZ axis of camera
- It is stilling customer to check motion movement |
khaw |
on going |
| AXI |
Defect Escape (DIMM) |
QMB |
- We need to retrain the AI model for both Type 1 and Type 2. Next time, please collect the Good Pins, Fail Pins, and missed-detection Pins for both Type 1 and Type 2, and the FAE team will perform the AI model training. |
khaw |
on going |
| AXI |
Out of Focus (OOF) for server board |
QMB |
- keep monitoring this issue and monitor false call at RS staion |
khaw |
on going |
| AXI |
RS AI Verify Host |
NA |
- Scott sent the new RS version to Bill, the location score of AI judgment is met Bill's require
- Bill said we still need to improve the AI coverage
- waiting customer send the RSAI images to retraining AI |
khaw |
on going |
| AXI |
Shield Can Defect |
Hanwha |
- RD tried to use two algorithms, “Solder Area” and “Open Sharpness”, were applied for component inspection. While all defects can be successfully detected, the false alarm rate remains relatively high.
- Will find the free time to fine-tune for reduce false call
- Currently, not yet continue fine-tine due to the x-ray will became blurry, sholud be solve the x-ray was blurry first |
khaw |
on going |
| AXI |
X-Ray image quality going blur after change the 2D fixture |
Hanwha |
- Maxym suggest to redo calibration by use official version |
khaw |
on going |
| AXI |
Dual Lane SMema has malfunction. [Delta 2] |
Delta |
1.RD request the PLC file. --> Already send to RD.
2.Require test upload & test PLC at line As11
--> Plan to test on 11-12 Jun 2026 |
june |
on going |
| AXI |
Main software malfunction when using multiple block scan |
Benchmark |
1.Send all log and RCP to RD --> Done (7/Jun/26)
2.RD require to testing with ver 3.6.92.2 (CAD Mode)
-->Test done , Found same issue both inspection mode.
3.Install Hwinfo for tracking CPU temp. & Continue followup with RD |
june |
on going |
| AXI |
X-ray power ON lamp broken |
Benchmark |
-Wait warranty claim part from Taiwan. |
june |
on going |