Issues for AXI (WW33/2026)

Machine Issue Customer Progress Executor Status
AXI Main software malfunction when using multiple block scan Benchmark Send SW the new version to Nichtech ton on going
AXI API Delta Develop auto assign function for multi models in one panel Delta - send the new version to customer again - Waiting customer test the new function - send the new version toDelta2 customer, wait for customer testing khaw on going
AXI Defect Escape (DIMM) QMB - waiting the DIMM type1 and type2 defected boards, then will collect the image to retrain AI model khaw on going
AXI RS AI Verify Host NA - Collected the aiokopng, aingopok from offline PC 2nd floor F10 building and send the image to Scott for retraining new AI model - Waiting for new AI model khaw on going
AXI X-Ray image quality going blur after change the 2D fixture Hanwha - Waiting HQ confirm whether will we should replace the tube or not khaw on going